Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Type | Material | Surface Treatment | Max. Operating Pressure | |||||||
Pitch (P) Standard | Pitch (P) Configurable | |||||||||
25 × 32 Sq. | 40 Sq. | 50 Sq. | 60 Sq. | 70 Sq. | 40 Sq. | 50 Sq. | 60 Sq. | |||
BMAS | BMAFA | BMAFL | BMAFLK | BMAL | BMAFPA | BMAFLP | BMAFLKP | Steel for General Structure | Trivalent Chromate | 20.6 MPa ≈ 210 kgf/cm2 or less |
— | BMAFMA | BMAFLM | — | BMALM | — | BMAFLMP | — | Electroless Nickel Plating | ||
BMASR | BMAFRA | BMAFLR | — | — | — | — | — | SUS304 | — | |
— | BMAFSA | — | — | — | — | — | — | SUS316 | ||
— | BMAFCA | — | — | — | — | — | — | Brass | 1 MPa ≈ 10 kgf/cm2 or less |
Part Number | — | Q | — | R | — | S | — | P | ||||||
Type | Mounting Hole Change | Number of Circuits | ||||||||||||
BMAF BMAFLP G−BMAFLP | NA NA | 4 3 3 | — — — | Q3 Q3 Q3 | — — — | R2 R4 R4 | — — — | S3 S4 S4 | — — | P45 P45 | (G Thread) |
Part Number | Rc (PT), NPT Selection | Pitch P | Number of Pitches N | Total Number of Q, R and S Threads | A | B | E | F | X | Y | Mounting Hole | ||||
Type | Mounting Hole Change | Number of Circuits | Q, R, S | Standard | Configurable 1mm Increment | M | |||||||||
(25x32 Sq.) | NA (Through) T (Tapped) ZT (Counterbore Tapped) YZ (Side Counterbore) YN (Side Through) | 1 | 1 (1/8) | - | - | 0 | 3 | 25 | 32 | 20 | 16 | 7.5 | 7 | M5 | |
Pitch Standard BMAS BMASR | 2 | 25 | 1 | 6 | |||||||||||
3 | 2 | 9 | |||||||||||||
4 | 3 | 12 | |||||||||||||
5 | 4 | 15 | |||||||||||||
6 | 5 | 18 | |||||||||||||
7 | 6 | 21 | |||||||||||||
8 | 7 | 24 | |||||||||||||
(40 Sq.) | 1 | - | - | 0 | 3 | 40 | 40 | 25 | 20 | 7.5 | 7 | M6 | |||
Pitch Standard BMAFA BMAFMA BMAFRA BMAFSA BMAFCA | Pitch Configurable BMAFPA | 2 | 1 (1/8) | 40 | 25~50 | 1 | 6 | ||||||||
3 | 2 (1/4) | 2 | 9 | ||||||||||||
4 | 3 (3/8) | 3 | 12 | ||||||||||||
5 | 1N (NPT1/8) | 4 | 15 | ||||||||||||
6 | 2N (NPT1/4) | 30~50 | 5 | 18 | |||||||||||
7 | 3N (NPT3/8) | 6 | 21 | ||||||||||||
(Standard Change: E dimension) | 8 | 7 | 24 | ||||||||||||
(50 Sq.) | 1 | - | - | 0 | 3 | 50 | 50 | 30 | 25 | 7.5 | 8 | M8 | |||
Pitch Standard BMAFL BMAFLM BMAFLR | Pitch Configurable BMAFLP BMAFLMP | 2 | 2 (1/4) | 60 | 35~60 | 1 | 6 | ||||||||
3 | 3 (3/8) | 2 | 9 | ||||||||||||
4 | 4 (1/2) | 3 | 12 | ||||||||||||
5 | 6 (3/4) | 4 | 15 | ||||||||||||
6 | 40~60 | 5 | 18 | ||||||||||||
(60 Sq.) | 1 | - | - | 0 | 3 | 60 | 60 | 30 | 30 | 7.5 | 8 | M8 | |||
Pitch Standard BMAFLK | Pitch Configurable BMAFLKP | 2 | 2 (1/4) | 60 | 35~60 | 1 | 6 | ||||||||
3 | 3 (3/8) | 2 | 9 | ||||||||||||
4 | 4 (1/2) | 3 | 12 | ||||||||||||
5 | 6 (3/4) | 4 | 15 | ||||||||||||
6 | 40~60 | 5 | 18 | ||||||||||||
(70 Sq.) | 1 | - | - | 0 | 3 | 70 | 70 | 40 | 35 | 10 | 10 | M8 | |||
Pitch Standard BMAL BMALM | 2 | 6 (3/4) | 60 | 1 | 6 | ||||||||||
3 | 8 (1) | 2 | 9 | ||||||||||||
4 | 3 | 12 |
3D preview is not available, because the part number has not yet been determined.
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | RoHS | Shape | Material | Surface Treatment | Block Size (mm) | Number of Circuits (Circuits) | Thread Size / Type | Mounting Hole Change | Pitch P (mm) | Pitch Standard / Configurable | Application | Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) | Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) | Select a value for PT/PF Thread Dia. on S (in Drawing). [S] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 1 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | - | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 2 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 3 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 4 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 5 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 50 x 50 | 6 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | - | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | - | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | Not Specified (Counterbore) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | NA (Through) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | YZ (Side Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | YZ (Side Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | YZ (Side Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | YZ (Side Counterbore) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | YZ (Side Counterbore) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 35 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | ZT (Counterbore Tapped) | 40 ~ 60 | Configurable Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | - | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | T (Tapped) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 1 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | - | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 2 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 3 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 4 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 5 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 | ||
- | 1 | 15 Days | 10 | T-Shaped Hole | Steel for General Structure | Trivalent Chromate | 60 x 60 | 6 | Standard Thread {PT, m (Coarse) Thread} | YN (Side Through) | 60 | Fixed Type | For hydraulic / Water Pressure | 2 ~ 6 | 2 ~ 6 | 2 ~ 6 |
Loading...
Configure
Basic Attributes
Shape
Material
Surface Treatment
Block Size(mm)
Number of Circuits(Circuits)
Thread Size / Type
Mounting Hole Change
Pitch P(mm)
Pitch Standard / Configurable
Application
Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)
Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)
Select a value for PT/PF Thread Dia. on S (in Drawing). [S] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)
Type
Filter by CAD data type
Filter by standard shipping days
Optional Attributes