Photoelectric Sensor in Compact Stainless Steel Housing [E3ZM] (Part Numbers - CAD Download)

Photoelectric Sensor in Compact Stainless Steel Housing [E3ZM]
  • Volume Discount
• Compact size SUS 316L housing for highest mechanical protection
• Tested detergent and chemical resistance (certified by Henkel-Ecolab)
• Watertight construction for highest protection when cleaned with high pressure

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
E3ZM-LS81H 2M
E3ZM-R61 2M
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Detected Objects Detection Method Optical axis arrangement type Beam Shape Light Source Head shape Case Material Detection distance [classification]
(mm)
Standard Detected Subject
(φ)
Reflection type detection method Operating Environment Head maximum size width
(mm)
Head maximum size height
(mm)
Head maximum size, depth
(mm)
Output Format Connection Method Detection head size (screw type)
(mm)
Detection head size (cylindrical)
(mm)
Cord Length
(m)
Timer Accessory functionality (non-amplifier) Spot Dia.
(mm)
Numbers of optical axis
(Optical axis)
Accessories (dedicated reflective plate, etc.) Laser class Shape (amplifier) Material (amplifier) Applicable Sensors Overview Shape (beam) Input/Output Strength (tightening)
(N▪m)
Opening Angle
(°)
Material (detection head) Mounting Method Combination lens Detection Distance details
(mm)
Free Cut Support Material of Cable Sheath Material of Optical Surface Scope of Delivery of the One-Way System Operation Agent-Safety Class Housing Material Setting Procedure Type of Switch Function Type of Light Construction Type Housing Analogue Output -10 V ... +10 V Pre Failure Notice With Reflector Number of Contact Energized Outputs With Signalling Function Number of Semiconductor Outputs With Signalling Function Max. Output Current
(mA)
Max. Switching Distance
(mm)
Transmission Range of the Safety Field
(m)
Min. Reflector Distance
(mm)
Switching Frequency
(Hz)
Rated Switching Distance
(mm)
Wavelength of the Sensor
(nm)
AWG-Number Triangulation Adjustment Range
(mm)
Degree of Protection (NEMA) Type of Interface for Safety Communication Explosion Safety Category for Dust Explosion Safety Category for Gas With Communication Interface CANOpen With Communication Interface INTERBUS With Communication Interface AS-Interface With Communication Interface PROFIBUS With Communication Interface SSI With Restart Blockage With Communication Interface RS-232 Analogue Output 0 mA ... 20 mA With Communication Interface RS-485 With Other Analogue Output With Communication Interface Ethernet With Communication Interface RS-422 Suitable for Safety Functions With Communication Interface Analogue With Monitoring Function Downstream Switching Devices With Communication Interface Devicenet Analogue Output 4 mA ... 20 mA With Communication Interface SSD Analogue Output 0 V ... 10 V Number of Protected Contact Energized Outputs Number of Protected Semiconductor Outputs Type of Safety According To IEC 61496-1

275.40 €

1 7 Days Opaque ObjectsRetro reflectiveEmitting and Receiving Integrated Single UseStandard[Red] Red light emitting diode[Square] Square shape[Stainless Steel] Stainless Steel (EN 1.4404 Equiv.)Up to 100-[BGS Reflection] BGS Reflection typeStandard / Cold Resistance2110.832.2PNP Open CollectorIntegrated Cable Type--2--≤ φ4 (@ 100-mm detection distance)---------0.5 (M3 screws)-Methacrylic Resin--10~100---------------------------------------------------

241.90 €

1 7 Days Opaque ObjectsRetro reflectiveUse of Emitting and Receiving Integrated Reflection PlateStandard[Red] Red light emitting diode[Square] Square shape[Stainless Steel] Stainless Steel (EN 1.4404 Equiv.)Up to 10075 mm[Retro-Reflective] Retro-Reflective Shape (With MSR Function)Standard / Cold Resistance2110.832.2NPN Open CollectorIntegrated Cable Type--2------------0.5 (M3 screws)-Methacrylic Resin--100---------------------------------------------------

Loading...

  1. 1

Basic information

Type Photoelectric Sensor Amplifier accessory type Amplifier Built-in Type Ambient Operating Temperature(°C) −25::55
Ambient Operating Humidity(%) 35::85 Protective Structure IP67 Power Supply Voltage(V) VDC 10–30
Operating Mode Light ON / dark ON switchable Response time (standard mode)(ms) 1

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360