Technical Data:

Applicable Fluid: Water

Operating Environment: Standard / Dust Resistant

Switching Type: Normally Open

Connection Type: G

Nominal Pipe Thread Size: 1/2


(i)Remark

  • Product images may be representative images. Refer to the catalog for details.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

VXD2B2KGA

Part Number
VXD2B2KGA
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Applicable Fluid Operating Environment Switching Type Connection Type Nominal Pipe Thread Size Tube Diameter Tube Flange Nominal Orifice Diameter
(mm)
Operating Pressure Differential Range
(MPa)
Insulation Class Pipe opening type (details) Voltage Sealing materials Lead wire exit direction Option Body material Bracket Detailed type Functions Lead wire electrical entry

167.02 €

1 58 Days WaterStandard / Dust ResistantNormally OpenG1/2--150.02~1BNone24 V DCNBRNoneNoneSUSNone-NoneDIN terminal (With surge voltage suppressor)

Loading...

  1. 1

Basic information

Type Electromagnetic Type Driving Type Pilot Type Operating Temperature Range(℃) -20::60
Number of Solenoids Single Solenoid Application Single Item Protection Rating IP65

This page is Pilot Operated 2 Port Solenoid Valve VXD Series, part number VXD2B2KGA.
You can find the detail information about specifications and dimensions on part number VXD2B2KGA.

Variation of this product

Part Number
VXD230AAB
VXD230AABXB
VXD230AABXCC
VXD2B2KGK
VXD2B2KGKXB
VXD2B2KGXB
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Applicable Fluid Operating Environment Switching Type Connection Type Nominal Pipe Thread Size Tube Diameter Tube Flange Nominal Orifice Diameter
(mm)
Operating Pressure Differential Range
(MPa)
Insulation Class Pipe opening type (details) Voltage Sealing materials Lead wire exit direction Option Body material Bracket Detailed type Functions Lead wire electrical entry

33.89 €

1 58 Days AirDust Resistant / StandardNormally ClosedNPT1/4--100.02~0.7BNone24 V DCNBRNoneNoneAluminumNone-NoneGrommet

35.68 €

1 58 Days AirDust Resistant / StandardNormally ClosedNPT1/4--100.02~0.7BNone24 V DCNBRStandardNoneAluminumIncluded-NoneGrommet

35.68 €

1 58 Days AirDust Resistant / StandardNormally ClosedNPT1/4--100.02~0.7BNone24 V DCNBR270°NoneAluminumNone-NoneGrommet

185.44 €

1 58 Days WaterDust Resistant / StandardNormally OpenG1/2--150.02~1BNone24 V DCFKMNoneCompatible with low concentration ozone, deionized water, etc. / Oil-freeSUSNone-NoneDIN terminal (With surge voltage suppressor)

188.98 €

1 58 Days WaterDust Resistant / StandardNormally OpenG1/2--150.02~1BNone24 V DCFKMStandardCompatible with low concentration ozone, deionized water, etc. / Oil-freeSUSIncluded-NoneDIN terminal (With surge voltage suppressor)

170.56 €

1 58 Days WaterDust Resistant / StandardNormally Open[Rc (R)] Rc1/2--150.02~1BNone24 V DCNBRStandardNoneSUSIncluded-NoneDIN terminal (With surge voltage suppressor)