Manufacturer part number: SM0510
Brand: IFM ELECTRONIC
Price: 1,208.08 €
Delivery time: 4 Days
Number of Inputs and Outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Analogue Voltage Output: 0-10; (scalable) V
Protection: IP 65; IP 67
Electrical Design: PNP/NPN
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PC; FKM; PBT-GF20; TPE-U
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
SM0510
Part Number
|
---|
SM0510 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Electrical Design | Materials | Current Consumption (mA) | Application | Type of Short-Circuit Protection | Process Connection | Storage Temperature (°C) | Operating Voltage (V) | Ambient Temperature (°C) | Output Function | Total Number of Outputs | Repeatability | Min. Load Resistance (Ω) | Frequency of the Output (Hz) | Output Signal | Short-Circuit Protection | Max. Voltage Drop Switching Output DC (V) | Communication Interface | Inputs | Measuring Range | Storage Temperature | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Ambient Temperature (°F) | Temperature Drift | Pulse Output | Accuracy (In the Measuring Range) | IO-Link Revision | Installation | Display | Measuring Range (l/min) | Materials (Wetted Parts) | Transmission Type | Accessories (Included) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,208.08 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PC; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | -25-80 | 18-32 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-600 l/min 0.3-36 m³/h | - | 250; (per output) | Yes | - | ± 0.0333 °C / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel |
Loading...
Power-On Delay Time(s) | 5 | Protection Class | III | Electrical Connection | Connector: 1 x M12; Contacts: gold-plated |
---|---|---|---|---|---|
Reverse Polarity Protection | Yes | Special Feature | Gold-plated contacts | Application Media | conductive liquids; water; hydrous media |
This page is Magnetic-Inductive Flow Meter, part number SM0510.
You can find the detail information about specifications and dimensions on part number SM0510.
Configure
Basic Attributes
Storage Temperature
Ambient Temperature(°F)
Measuring Range(l/min)
Number of Inputs and Outputs
Analogue Voltage Output(V)
Protection
Electrical Design
Materials
Current Consumption(mA)
Application
Type of Short-Circuit Protection
Process Connection
Storage Temperature(°C)
Operating Voltage(V)
Ambient Temperature(°C)
Output Function
Total Number of Outputs
Repeatability
Min. Load Resistance(Ω)
Frequency of the Output(Hz)
Output Signal
Short-Circuit Protection
Max. Voltage Drop Switching Output DC(V)
Communication Interface
Inputs
Measuring Range
Permanent Current Rating of Switching Output DC(mA)
Overload Protection
Temperature Drift
Pulse Output
Accuracy (In the Measuring Range)
IO-Link Revision
Installation
Display
Materials (Wetted Parts)
Transmission Type
Accessories (Included)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
SM0504 |
SM0505 |
SM2000 |
SM2001 |
SM2004 |
SM2100 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Electrical Design | Materials | Current Consumption (mA) | Application | Type of Short-Circuit Protection | Process Connection | Storage Temperature (°C) | Operating Voltage (V) | Ambient Temperature (°C) | Output Function | Total Number of Outputs | Repeatability | Min. Load Resistance (Ω) | Frequency of the Output (Hz) | Output Signal | Short-Circuit Protection | Max. Voltage Drop Switching Output DC (V) | Communication Interface | Inputs | Measuring Range | Storage Temperature | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Ambient Temperature (°F) | Temperature Drift | Pulse Output | Accuracy (In the Measuring Range) | IO-Link Revision | Installation | Display | Measuring Range (l/min) | Materials (Wetted Parts) | Transmission Type | Accessories (Included) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
956.59 € | 1 | 12 Days | Number of analogue outputs: 2 | - | IP 67 | - | stainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM/X | 95; (24 V) | For industrial applications | - | threaded connection G 1 DN25 flat seal | - | 18-30 DC; (according to EN 50178 SELV/PELV) | - | - | 2 | ± 0.2% MEW | - | - | Analogue signal | - | - | - | - | 6-1800 gph 0.1-30 gpm | - | - | Yes | 14-140 | - | - | ± (0.8 % MW + 0.5 % MEW) | - | connection to pipe by means of an adapter | - | - | stainless steel (1.4404 / 316L); Hastelloy; PEEK; FKM | - | - | ||
938.44 € | 1 | 12 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM/X | 95; (24 V) | empty pipe detection; totaliser function; for industrial applications | pulsed | threaded connection G 1 DN25 flat seal | -25-80 | 18-30 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | - | Switching signal; analogue signal; pulse signal; (configurable) | Yes | 2 | - | counter reset | 0.2-100 l/min 0.01-6 m³/h | - | 200 | Yes | - | - | flow rate meter | ± (2 % MW + 0.5 % MEW) | - | - | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); PEEK; EPDM/X | - | - | ||
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | -25-80 | 18-32 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-600 l/min 0.3-36 m³/h | - | 250; (per output) | Yes | - | ± 0.0333 °C / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel | ||
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 80-9600 gph 1.3-160 gpm | - | 250; (per output) | Yes | 14-140 | ± 0.0185 °F / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel | ||
1,185.32 € | 1 | 4 Days | Number of analogue outputs: 2 | - | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | empty pipe detection; for industrial applications | - | threaded connection G 2 DN50 flat seal | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | - | 2 | ± 0.2% MEW | - | - | Analogue signal | - | - | - | - | 5-600 l/min 0.3-36 m³/h | -10-60 °C 14-140 °F -25-80 °C -13-176 °F Protection IP 65; IP 67 | - | - | - | ± 0.0333 °C / K; ± 0.0599 °F / K | - | ± (0.8 % MW + 0.5 % MEW) | - | connection to pipe by means of an adapter | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; NBR reinforced fibre; FKM | - | Sealing: 2, CentellenLabel | ||
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | -25-80 | 18-32 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-600 l/min 0.3-36 m³/h | - | 250; (per output) | Yes | - | ± 0.0333 °C / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel |