Manufacturer part number: SM2601
Brand: IFM ELECTRONIC
Price: 1,169.34 €
Delivery time: 4 Days
Number of Inputs and Outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Analogue Voltage Output: 0-10; (scalable) V
Protection: IP 65; IP 67
Electrical Design: PNP/NPN
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
SM2601
Part Number
|
---|
SM2601 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Electrical Design | Materials | Current Consumption (mA) | Application | Type of Short-Circuit Protection | Process Connection | Storage Temperature (°C) | Operating Voltage (V) | Ambient Temperature (°C) | Output Function | Total Number of Outputs | Repeatability | Min. Load Resistance (Ω) | Frequency of the Output (Hz) | Output Signal | Short-Circuit Protection | Max. Voltage Drop Switching Output DC (V) | Communication Interface | Inputs | Measuring Range | Storage Temperature | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Ambient Temperature (°F) | Temperature Drift | Pulse Output | Accuracy (In the Measuring Range) | IO-Link Revision | Installation | Display | Measuring Range (l/min) | Materials (Wetted Parts) | Transmission Type | Accessories (Included) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection 2"NPT DN50 | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 80-9600 gph 1.3-160 gpm | - | 250; (per output) | Yes | 14-140 | ± 0.0185 °F / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | - | Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM | COM2 (38.4 kBaud) | Label |
Loading...
Power-On Delay Time(s) | 5 | Protection Class | III | Electrical Connection | Connector: 1 x M12; Contacts: gold-plated |
---|---|---|---|---|---|
Reverse Polarity Protection | Yes | Special Feature | Gold-plated contacts | Application Media | conductive liquids; water; hydrous media |
This page is Magnetic-Inductive Flow Meter, part number SM2601.
You can find the detail information about specifications and dimensions on part number SM2601.
Configure
Basic Attributes
Storage Temperature(°C)
Ambient Temperature(°C)
Storage Temperature
Installation
Measuring Range(l/min)
Number of Inputs and Outputs
Analogue Voltage Output(V)
Protection
Electrical Design
Materials
Current Consumption(mA)
Application
Type of Short-Circuit Protection
Process Connection
Operating Voltage(V)
Output Function
Total Number of Outputs
Repeatability
Min. Load Resistance(Ω)
Frequency of the Output(Hz)
Output Signal
Short-Circuit Protection
Max. Voltage Drop Switching Output DC(V)
Communication Interface
Inputs
Measuring Range
Permanent Current Rating of Switching Output DC(mA)
Overload Protection
Ambient Temperature(°F)
Temperature Drift
Pulse Output
Accuracy (In the Measuring Range)
IO-Link Revision
Display
Materials (Wetted Parts)
Transmission Type
Accessories (Included)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
SM2000 |
SM2001 |
SM2004 |
SM2604 |
SM4000 |
SM4100 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Electrical Design | Materials | Current Consumption (mA) | Application | Type of Short-Circuit Protection | Process Connection | Storage Temperature (°C) | Operating Voltage (V) | Ambient Temperature (°C) | Output Function | Total Number of Outputs | Repeatability | Min. Load Resistance (Ω) | Frequency of the Output (Hz) | Output Signal | Short-Circuit Protection | Max. Voltage Drop Switching Output DC (V) | Communication Interface | Inputs | Measuring Range | Storage Temperature | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Ambient Temperature (°F) | Temperature Drift | Pulse Output | Accuracy (In the Measuring Range) | IO-Link Revision | Installation | Display | Measuring Range (l/min) | Materials (Wetted Parts) | Transmission Type | Accessories (Included) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | -25-80 | 18-32 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-600 l/min 0.3-36 m³/h | - | 250; (per output) | Yes | - | ± 0.0333 °C / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel | ||
1,169.34 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 65; IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | totaliser function; empty pipe detection; for industrial applications | pulsed | threaded connection G 2 DN50 flat seal | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | 0.1-10000 | Switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 80-9600 gph 1.3-160 gpm | - | 250; (per output) | Yes | 14-140 | ± 0.0185 °F / K | flow rate meter | ± (0.8 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKM | COM2 (38.4 kBaud) | Sealing: 2, CentellenLabel | ||
1,185.32 € | 1 | 4 Days | Number of analogue outputs: 2 | - | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | empty pipe detection; for industrial applications | - | threaded connection G 2 DN50 flat seal | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | - | 2 | ± 0.2% MEW | - | - | Analogue signal | - | - | - | - | 5-600 l/min 0.3-36 m³/h | -10-60 °C 14-140 °F -25-80 °C -13-176 °F Protection IP 65; IP 67 | - | - | - | ± 0.0333 °C / K; ± 0.0599 °F / K | - | ± (0.8 % MW + 0.5 % MEW) | - | connection to pipe by means of an adapter | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; NBR reinforced fibre; FKM | - | Sealing: 2, CentellenLabel | ||
1,185.32 € | 1 | 4 Days | Number of analogue outputs: 2 | - | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U | < 150 | empty pipe detection; for industrial applications | - | threaded connection 2"NPT DN50 | - | 18-32 DC; (according to EN 50178 SELV/PELV) | - | - | 2 | ± 0.2% MEW | - | - | Analogue signal; IO-Link; (configurable) | - | - | IO-Link | - | 5-600 l/min 0.3-36 m³/h | -10-60 °C 14-140 °F -25-80 °C -13-176 °F Protection IP 65; IP 67 | - | - | - | ± 0.0333 °C / K; ± 0.0599 °F / K | - | ± (0.8 % MW + 0.5 % MEW) | 1.1 | - | - | - | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM | COM2 (38.4 kBaud) | Label | ||
744.77 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE | < 80 | totaliser function; for industrial applications | pulsed | threaded connection G 1/4 DN6 flat seal | -25-80 | 18-30 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2% MEW | 2000 | - | Switching signal; analogue signal; pulse signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-3000 ml/min 0.005-3 l/min|5-3000 ml/min 0.005-3 l/min | - | 200 | Yes | - | - | flow rate meter | ± (2 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (ml/min, l/h, l, m³, °C, 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); PEEK; FKM | COM2 (38.4 kBaud) | - | ||
744.77 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | IP 67 | PNP/NPN | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE | < 80 | totaliser function; for industrial applications | pulsed | threaded connection G 1/4 DN6 flat seal | -25-80 | 18-30 DC; (according to EN 50178 SELV/PELV) | -10-60 | normally open / normally closed; (parameterisable) | 2 | ± 0.2 % MEW | 2000 | - | Switching signal; analogue signal; pulse signal; IO-Link; (configurable) | Yes | 2 | IO-Link | counter reset | 5-3000 ml/min 0.005-3 l/min|5-3000 ml/min 0.005-3 l/min | - | 200 | Yes | - | - | flow rate meter | ± (2 % MW + 0.5 % MEW) | 1.1 | connection to pipe by means of an adapter | Display unit: 6 x LED, green (ml/min, l/h, l, m³, °C, 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | - | stainless steel (1.4404 / 316L); PEEK; EPDM | COM2 (38.4 kBaud) | - |