Digital I/O Slave Unit with Clamp Terminals [CRT1-□D16SL(-1)] (Part Numbers)

Digital I/O Slave Unit with Clamp Terminals [CRT1-□D16SL(-1)]
Screw-less Terminal Wiring Further Reduces Wiring Work and Saves Labor at the Production Site.
• Screw-less (M3) design reduces the need for extra tightening.
• Removable terminal block gives powerful support to maintenance work.
• One-step wiring. Wire simply by inserting the ferrules.
• Applicable wire: AWG24 to AWG16 (cross-section: 0.2 to 1.25 mm²

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

CRT1-OD16SL-1

Part Number
CRT1-OD16SL-1
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?

837.33 €

1 3 Days

Loading...

  1. 1

Basic information

Number of Outputs 16 Output Format PNP Representative Standard U / N
Output Current(A) 0.5 Performance Level According to EN ISO 13849-1 Level a Depth(mm) 60.3
Height(mm) 52 Width(mm) 132 Voltage Type (Supply Voltage) DC
Type of Electric Connection Spring clamp connection Type of Digital Output Transistor Type of Output Voltage DC
SIL According to IEC 61508 None Explosion Safety Category for Dust None Explosion Safety Category for Gas None
Number of HW-Interfaces Industrial Ethernet 0 Number of Digital Inputs 0 Number of Digital Outputs 16
Permitted Voltage at Output(V) 0 - 26.4 Time Delay at Signal Change(ms) 0.5 - 1.5 Supply Voltage DC(V) 20.4 - 26.4
Degree of Protection (IP) IP20 Number of Interfaces PROFINET 0 Number of HW-Interfaces Other 1
Wall mounting/direct mounting false Suitable for rail mounting true Suitable for safety functions false
Short-circuit protection, outputs available false System accessory false IO link master false
Fieldbus connection over separate bus coupler possible false Supporting protocol for INTERBUS-Safety false Supporting protocol for KNX false
Supporting protocol for PROFINET CBA false Supporting protocol for SafetyBUS p false Supporting protocol for SUCONET false
Supporting protocol for INTERBUS false Supporting protocol for Data-Highway false Supporting protocol for DeviceNet false
Supporting protocol for other bus systems true Supporting protocol for CAN false Supporting protocol for PROFIsafe false
Supporting protocol for Foundation Fieldbus false Supporting protocol for PROFINET IO false Supporting protocol for AS-Interface Safety at Work false
Supporting protocol for TCP/IP false Supporting protocol for Modbus false Supporting protocol for SERCOS false
Supporting protocol for LON false Supporting protocol for DeviceNet Safety false Supporting protocol for EtherNet/IP false
Supporting protocol for PROFIBUS false Number of HW-interfaces USB 0 Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-485 0 Number of HW-interfaces RS-422 0

This page is Digital I/O Slave Unit with Clamp Terminals [CRT1-□D16SL(-1)], part number CRT1-OD16SL-1.
You can find the detail information about specifications and dimensions on part number CRT1-OD16SL-1.

Tech Support